Şəkil təsvir ola bilər.
Məhsul təfərrüatları üçün spesifikasiyalara baxın.
MAX811LEUS-T

MAX811LEUS-T

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Monitor with Manual Reset
  • Characteristics: Low-power, precision voltage monitor with manual reset input
  • Package: SOT-143
  • Essence: Monitors the power supply voltage and provides a reset signal to the system when the voltage drops below a specified threshold
  • Packaging/Quantity: Tape and Reel, 3000 units per reel

Specifications

  • Supply Voltage Range: 1.6V to 5.5V
  • Reset Threshold Options: 2.93V, 3.08V, 3.3V, 4.38V
  • Manual Reset Input: Active-low push-button input for manual reset
  • Reset Timeout Period: 140ms (typical)
  • Quiescent Current: 7µA (typical)
  • Operating Temperature Range: -40°C to +85°C

Pin Configuration

The MAX811LEUS-T has the following pin configuration:

| Pin Name | Description | |----------|-------------| | GND | Ground | | MR | Manual Reset Input | | RESET | Reset Output | | VCC | Supply Voltage |

Functional Features

  1. Voltage Monitoring: The MAX811LEUS-T continuously monitors the supply voltage and compares it to the preset threshold.
  2. Manual Reset: It provides a manual reset input that allows the user to manually reset the system.
  3. Reset Output: When the supply voltage drops below the threshold, the MAX811LEUS-T asserts the reset output, signaling the system to reset.
  4. Reset Timeout: The reset output remains asserted for a fixed timeout period after the supply voltage rises above the threshold.

Advantages and Disadvantages

Advantages

  • Low-power consumption
  • Precision voltage monitoring
  • Manual reset capability
  • Small package size (SOT-143)
  • Wide operating temperature range

Disadvantages

  • Limited reset threshold options
  • Single-channel voltage monitoring

Working Principles

The MAX811LEUS-T operates by continuously monitoring the supply voltage using an internal voltage reference and comparator. When the voltage drops below the preset threshold, the reset output is asserted, indicating a power failure or low voltage condition. The reset output remains active for a fixed timeout period after the voltage rises above the threshold to ensure stable operation.

Application Field Plans

The MAX811LEUS-T is commonly used in various applications where reliable voltage monitoring and system reset functionality are required. Some potential application fields include:

  1. Embedded Systems: Used in microcontroller-based systems to ensure proper operation during power fluctuations.
  2. Industrial Automation: Provides voltage monitoring and reset capabilities in industrial control systems.
  3. Consumer Electronics: Used in devices such as smart home appliances, IoT devices, and wearable gadgets to ensure reliable operation.

Alternative Models

  1. MAX811L: Similar to MAX811LEUS-T but with different package options (SOT-23, SOT-23-5).
  2. MAX813: Dual-channel voltage monitor with manual reset input.
  3. MAX809: Voltage monitor with adjustable reset threshold and watchdog timer functionality.

Note: This entry provides a brief overview of the MAX811LEUS-T. For detailed information, please refer to the product datasheet and specifications provided by the manufacturer.

Word Count: 416

Texniki həllərdə MAX811LEUS-T tətbiqi ilə bağlı 10 ümumi sual və cavabı sadalayın

Sure! Here are 10 common questions and answers related to the application of MAX811LEUS-T in technical solutions:

  1. Q: What is the MAX811LEUS-T? A: The MAX811LEUS-T is a microprocessor supervisory circuit that monitors the power supply voltage of a microcontroller or other digital systems.

  2. Q: What is the purpose of using the MAX811LEUS-T? A: The MAX811LEUS-T ensures proper operation of the microcontroller by monitoring the power supply voltage and generating a reset signal if the voltage falls below a specified threshold.

  3. Q: How does the MAX811LEUS-T work? A: The MAX811LEUS-T continuously monitors the power supply voltage using an internal voltage reference. If the voltage drops below the threshold, it holds the microcontroller in reset until the voltage rises above the threshold again.

  4. Q: What is the operating voltage range of the MAX811LEUS-T? A: The MAX811LEUS-T operates with a supply voltage range of 1.0V to 5.5V.

  5. Q: Can the MAX811LEUS-T be used with different microcontrollers? A: Yes, the MAX811LEUS-T can be used with a wide range of microcontrollers and other digital systems as long as the supply voltage requirements are within its operating range.

  6. Q: Does the MAX811LEUS-T have any adjustable parameters? A: No, the MAX811LEUS-T does not have any adjustable parameters. It has fixed threshold voltages for monitoring the power supply.

  7. Q: What is the typical reset timeout period of the MAX811LEUS-T? A: The typical reset timeout period of the MAX811LEUS-T is 140ms.

  8. Q: Can the MAX811LEUS-T generate an active-low or active-high reset signal? A: The MAX811LEUS-T generates an active-low reset signal, which means it pulls the reset pin low when a reset condition is detected.

  9. Q: Is the MAX811LEUS-T available in different package options? A: Yes, the MAX811LEUS-T is available in a SOT-143 package.

  10. Q: Are there any additional features of the MAX811LEUS-T? A: Yes, the MAX811LEUS-T also includes a manual reset input and a watchdog timer function for additional system monitoring capabilities.

Please note that these answers are general and may vary depending on the specific datasheet and application requirements.