The INA148UA/2K5G4 belongs to the category of precision instrumentation amplifiers.
It is commonly used for precise signal amplification in various electronic circuits and systems.
The INA148UA/2K5G4 comes in a small outline package (SOIC) with 8 pins.
The essence of the INA148UA/2K5G4 lies in its ability to accurately amplify weak signals while rejecting common-mode noise.
The INA148UA/2K5G4 is typically packaged in reels containing a specific quantity, usually 2500 units per reel.
The INA148UA/2K5G4 operates based on the principles of differential amplification, where it amplifies the difference between the non-inverting and inverting inputs while rejecting common-mode signals.
The INA148UA/2K5G4 finds extensive use in: - Medical instrumentation - Industrial control systems - Test and measurement equipment - Data acquisition systems - Precision sensor interfaces
Some alternative models to the INA148UA/2K5G4 include: - AD620 - AD8221 - LT1167 - MAX4209
In conclusion, the INA148UA/2K5G4 is a precision instrumentation amplifier known for its high accuracy, low noise, and wide application in various electronic systems requiring precise signal amplification.
[Word Count: 366]
What is the typical supply voltage range for INA148UA/2K5G4?
- The typical supply voltage range for INA148UA/2K5G4 is 2.7V to 36V.
What is the input offset voltage of INA148UA/2K5G4?
- The input offset voltage of INA148UA/2K5G4 is typically 50µV.
Can INA148UA/2K5G4 be used in single-supply applications?
- Yes, INA148UA/2K5G4 can be used in single-supply applications.
What is the gain bandwidth product of INA148UA/2K5G4?
- The gain bandwidth product of INA148UA/2K5G4 is typically 1.8MHz.
Is INA148UA/2K5G4 suitable for precision instrumentation applications?
- Yes, INA148UA/2K5G4 is suitable for precision instrumentation applications.
What is the common-mode rejection ratio (CMRR) of INA148UA/2K5G4?
- The CMRR of INA148UA/2K5G4 is typically 100dB.
Can INA148UA/2K5G4 be used in temperature measurement systems?
- Yes, INA148UA/2K5G4 can be used in temperature measurement systems.
What is the maximum input offset voltage drift over temperature for INA148UA/2K5G4?
- The maximum input offset voltage drift over temperature for INA148UA/2K5G4 is typically 0.5µV/°C.
Is INA148UA/2K5G4 suitable for industrial control and automation applications?
- Yes, INA148UA/2K5G4 is suitable for industrial control and automation applications.
What is the maximum common-mode input voltage range for INA148UA/2K5G4?
- The maximum common-mode input voltage range for INA148UA/2K5G4 is equal to the supply voltage range.